Abstract: Abstract:Inordertoaccuratelydeterminethesiliconcontentinferrosiliconandmanganesesiliconal
loys,thenationalstandardrecommendedmethodofperchloricaciddehydrationweightmethodwassuc
cessivelyusedfortesting.Duetothehighrequirementsforsodiumperoxidesolidfluxusedinthenation
alstandardmethod,itisdifficulttomasterduringthesamplemeltingprocessofthetestmethod.The
fluxiseasytosplashandoverflowduringthetest,andthesampleisalsolostwiththeoverflowofthe
flux,resultinginlowandunstablemeasurementresults.Themethodusesgranularsodiumhydroxideto
meltinsteadofsodiumperoxideastheflux,meltsinahightemperaturemufflefurnaceat650℃ for15
minutes,andreferstotheperchloricaciddehydrationstepandwashes.Thetemperaturewasslowlyand
slowlyincreasedfrom400℃ to650℃ inamufflefurnace.Thefilterpaperandsamplewereashened,
ignited,andconstantweight.ICPmethodwasusedtodeterminethepercentageofresidualsiliconinthe
filtratetoverifythelotioneffectandstability.Therelativestandarddeviationofthemethodtestresultsis
between015% and122%,thedeviationofthetestresultsislessthan035% specifiedinthenation
alstandard,andtheaccuracymeetstheallowabledeviationofthecurrentnationalstandardmethod.

Key words: Keywords:ferrosilicon, manganesesilicon, weightmethod, sodium hydroxidemelting, perchloric
aciddehydration