欢迎访问昆明冶金高等专科学校学报官方网站,今天是 分享到:

昆明冶金高等专科学校学报 ›› 2023, Vol. 39 ›› Issue (2): 75-.DOI: 10.3969/j.issn.1009-0479.2023.02.010

• 环境保护与化工技术 • 上一篇    下一篇

Fe/硅藻土、Fe/ZSM-5非均相 Fenton处理垃圾渗滤液的研究

李 理1 ,宁门翠1 ,宋 煜1 ,谭艳霞1 ,徐孝静2 ,彭 莉1 ,吴文彬1
  

  1. (1昆明冶金高等专科学校 环境与化工学院,云南 昆明 650033;2昆明绿岛环境科技有限公司,云南 昆明 650228)
  • 收稿日期:2023-02-27 出版日期:2023-04-30 发布日期:2023-11-13
  • 作者简介:李理 (1979-),男,云南石屏人,工学硕士,副教授,主要从事环境检测与污染治理技术研究。
  • 基金资助:
    云南省教育厅科学研究基金项目:Fe/硅藻土催化剂的制备及其催化氧化垃圾渗滤液研究 (2020J0767)。

The Treatment of Landfill Leachate by Fe/Diatomite and Fe/ZSM-5 Non-homogeneous Fenton

LI Li1 , NING Mencui1 , SONG Yu1,TAN Yanxia1 Xiaojing2,PENG Li1 , WU Wenbin1   

  1. (1. Faculty of Environment and Chemical Engineering, Kunming Metallurgy College , Kunming 650033, China;2. Kunming Green Island Environmental Technology Co. , Ltd. , Kunming 650228 , China)
  • Received:2023-02-27 Online:2023-04-30 Published:2023-11-13

摘要:

以硅藻土、ZSM5分子筛为载体,以 Fe(NO3)3·9H2O为 Fe源,制备了 Fe/硅藻土、Fe/ZSM5两种催化剂,分别与 H2O2组成非均相 Fenton体系处理垃圾渗滤液。研究了溶液 pH值、温度、H2O2用量、催化剂加入量和反应时间对垃圾渗滤液 COD去除效果的影响。实验结果表明,利用该非均相 Fenton体系处理 COD浓度为1110mg/L的垃圾渗滤液,在溶液体系 pH值为 30,反应温度 30℃,催化剂投加量折合浓度为 16g/L,H2O2加入量折合浓度为 02mol/L,反应时间 60min的条件下,Fe/硅藻土、Fe/ZSM5两种催化剂处理垃圾渗滤液COD去除率可分别达到 8878%和 9258%。

关键词:


Abstract: Using diatomite and ZSM-5 molecular sieve as carriers and Fe(NO, ),9H,0 as the Fe sourceIwo catalysts, two catalysts , Fe/diatomite and Fe/ZSM-5 , were prepared to treat landfill leachate withH,0, in a non-homogeneous Fenton system. The effects of solution pH, temperature, H,0, dosage , cat.alyst addition and reaction time on the COD removal of landfill leachate were investigated. The experimental results show that the COD removal rates of Fe/diatomite and Fe/ZSM-5 catalysts can reach88. 78% and 92. 58% respectively under the conditions that the pH value of the solution system is 3.0the reaction temperature is 30 C , the equivalent concentration of catalyst dosage is 1. 6 g/L, the equiva-ent concentration of H,0, dosage is 0. 2 mol/L, and the reaction time is 60 min.

Key words: